EcoventDryer Duct Solutions
  1. Home
  2. Dryer vent inspection

Inspection · airflow test

Dryer vent inspection and airflow test, before you need a cleaning or a repair

The whole run looked at, from the connection behind the dryer to the exterior hood, and the exhaust measured with the dryer running. For a home purchase, a new dryer, a burning smell, or a landlord’s yearly check.

  • 5.0 on Google · 99 reviews
  • Open 24/7
  • NADCA standard
Inside a dryer exhaust duct caked with lint, the kind of run an inspection finds before it becomes a fire

The short answer

What is a dryer vent inspection, and when do you need one?

A dryer vent inspection is the first and last steps of every Ecovent cleaning, done on their own. The technician traces the run from the connection behind the dryer to where it exits the house, checks the material, the length, the number of elbows and the state of the exterior hood and flap, then runs the dryer and tests the airflow at the exit. You get a plain answer: the vent is clear, the vent needs cleaning, or something in the run needs a repair or a replacement.

It is the right call when you are buying a home in Pinellas or Pasco and the home inspector only glanced at the laundry closet; when a new dryer is going in and the old run is a question mark; when there is a burning smell; when clothes still take two cycles after a recent cleaning; or when a landlord wants a yearly check on a rental. If the inspection shows a cleaning is needed, ask about doing it on the same visit. Call (844) 422-7680 for a free quote.

When to book one

When is an inspection the right call instead of a cleaning?

Six situations where the question is not “is it dirty” but “what is actually back there.”

Buying a home

A home inspection rarely goes past the laundry closet. Before closing, know whether the run is rigid metal or vinyl, where it exits, and whether it was ever cleaned.

A new dryer going in

A new machine on an old, restricted run dries no better than the last one and works harder. Check the run before the delivery crew connects it.

A burning smell

Stop using the dryer. Lint near the heating element scorches before it burns, and the inspection finds whether the cause is the run, the connection or the machine.

Still two cycles after a cleaning

If a cleaning did not fix the drying time, the restriction is not lint: a crushed section, a disconnected joint or a stuck flap. The airflow test finds which.

A rental, once a year

Landlords and property managers get a yearly check on each unit, and the cleaning when it is needed rather than on a guess.

After roof work, or a nest at the hood

Roofers disturb roof jacks, and birds love a warm vent. If either has happened, the termination and the top of the run need a look.

What gets checked

What does the technician look at on a dryer vent inspection?

Every part of the run, in order, from the machine to the outside air. Most Florida runs are hidden for most of their length, so the airflow test at the end is what confirms what the eye could not reach.

  • The connection behind the dryerCrushed or kinked flex hose, foil or vinyl where rigid metal belongs, and joints held with screws that catch lint.
  • The material and the jointsRigid metal, semi-rigid, foil or plastic; taped or screwed; any section that has separated inside a wall or the attic.
  • The length and the elbowsHow far the run travels and how many turns it takes. Every elbow collects lint and shortens the distance a dryer can push air.
  • The hidden sectionsWhat is reachable in the attic is checked by eye; the rest is read from the airflow at the exit.
  • The hood, the flap and any screenWhether the flap opens when the dryer runs, whether salt air has pitted it shut, and whether a screen is catching lint.
  • The airflow, with the dryer runningMeasured at the termination. A clear-looking run that moves too little air has a problem in the middle.

Book an inspection

Tell us why you want the run looked at and where the vent exits. We call you back with a price.

Free quote, no obligation. 5.0 on Google across 99 reviews.

What you get

Three possible answers, and what happens next

  1. 01

    The run is clear

    The airflow test passes and the run is sound. Nothing is sold. You get the date and a yearly interval to work from.

  2. 02

    The run needs cleaning

    Lint, debris or an obstruction is restricting the exhaust. A cleaning clears the whole run; ask about doing it on the same visit.

  3. 03

    Something needs a repair or replacing

    A crushed section, a disconnected joint, the wrong material or a failed hood. The inspection names it, and the repair or replacement is quoted separately, with no obligation.

Good questions

What people ask before they book an inspection

How long does a dryer vent inspection take?

Less time than a cleaning. The run is traced from the connection behind the dryer to the exit, the hood and flap are checked, and the exhaust is tested with the dryer running. If a cleaning follows, most are finished in under an hour, so the whole visit is usually well inside a morning or an afternoon.

Is the inspection free?

The quote is free and carries no obligation. Ask by phone what an inspection costs for your run, and if you expect it to turn into a cleaning on the same visit, ask how the two are priced together. There is no flat rate to print, because a garage dryer venting through a wall and an interior closet venting to a roof are not the same inspection.

What is an airflow test?

The dryer is run and the exhaust is measured at the termination, so the answer is not “it looks clear” but “it is moving air the way a dryer needs.” A run can look clean at both ends and still be restricted by a crushed section, a disconnected joint or a mat of lint at an elbow in the middle. The airflow test is what finds that.

Can you inspect a vent I cannot see?

Yes. Most of a Florida run is hidden: it leaves the laundry closet, crosses the attic or a wall cavity and comes out at the roof or a side wall. The technician traces it from both ends, checks what is reachable from the attic, and reads the rest from the airflow. If a section is damaged, that shows up as air that does not arrive at the exit.

Is a screen on the vent hood a problem?

Yes. A screen catches lint and clogs, which is why the residential code calls for a backdraft damper with no screen at a dryer exhaust termination. Builders and pest companies still fit them to keep birds out. The inspection notes it, and the fix is a proper hood with a flap that swings open when the dryer runs.

Do you inspect commercial dryer vents?

Yes. A laundromat, salon or hotel laundry that has never had its runs looked at usually starts with an inspection, and the cleaning schedule follows from what it shows. See commercial dryer vent cleaning.

Know what is behind the dryer before it matters.

Ask what an inspection costs for your run. The quote is free by phone or form, with no obligation.